CARTUCHO 6009 3M PDF

()*, , , , et S 3MMC. IMPORTANT: Conserver ces directives d’utilisation à titre de référence. Cartucho Serie Instrucciones. cartucho/filtro If the 3MTM Mercury . El Adaptador para Filtros/ Cartuchos de 3MMR está Mercurio de 3MMR, coloque los cartuchos en la. Cheap filter respirator, Buy Quality gas protection directly from China gas mask filter Suppliers: 3M gas mask filter Genuine guarantee against Mercury.

Author: Zolojinn Kegrel
Country: Vietnam
Language: English (Spanish)
Genre: Health and Food
Published (Last): 3 June 2015
Pages: 400
PDF File Size: 18.19 Mb
ePub File Size: 9.39 Mb
ISBN: 368-7-43962-638-2
Downloads: 12951
Price: Free* [*Free Regsitration Required]
Uploader: Fenrira

Replace if gasket is warped, distorted, cracked or split.

– Google+

Replace the gasket if it is warped, distorted, cut, split or cannot. Do not alter, abuse or misuse this respirator. The mercury 3j cartridges must be discarded when the ESLI changes to the discard color found on the mercury. To use the 3M combination dual airline breathing tubes SA and SA without cartridges or fi lters, attach.

Do not exceed maximum use concentrations established by local regulatory agencies. Do not use for concentrations of contaminants which are immediately dangerous to life or health, are unknown or. This respirator does not supply oxygen when used in air-purifying mode.

3M™ Mercury Vapor or Chlorine Acid Gas Cartridge / 3M-6009

While holding the facepiece in place, pull the head harness to back of head Fig. Certain organic vapors, chlorine, hydrogen chloride. Therefore, either qualitative or. Push the gasket groove onto the plastic bar and seat the gasket. This respirator must be inspected before each use to ensure it is in good operating condition.

  CQI-15 WELDING PDF

Division des produits de protection individuelle de 3M. If respirator becomes damaged, leave the contaminated area immediately and repair or replace the respirator. Respirator parts should be inspected prior to each use.

Silicone, Large S Full Facepieces. Formaldehyde and certain organic vapors and particulates. Replace worn or deteriorated parts with new parts before use. Cartuchoo all attachments are secure prior to each use. Align the cartridge notch with the small solid bayonet lug on facepiece cartycho push together. D – Air-line respirators can be used only when the respirators are supplied with respirable air meeting the.

Using both hands press or squeeze fi lter covers toward facepiece and inhale gently. Comments to this Manuals Your Name.

Before use, the wearer must read and understand these User Instructions. Pour tout renseignement sur. If the valve seat is damaged, replace the removable DIN connector Certain organic vapors, chlorine, hydrogen chloride, and. Replace the gaskets if they are warped, distorted, cut or split. Turn fi lter clockwise until it is fi rmly seated and cannot be further turned Fig.

cartuucho Storage, Transportation and Care: Place fi lter onto the fi lter holder so that fi lter comes into even contact with gasket.

Don’t show me this message again. Dispose of used product in accordance with applicable regulations. Do not use for respiratory.

  HANNS JOHST SCHLAGETER PDF

For Xartucho Dual Airline where cartridges or fi lters are attached perform user seal check as described. Page of 2 Go. Loosen the adapter nuts and position cartridge to desired location.

To print the manual completely, please, download it.

Fit Tested, and up to times the PEL in powered air. H – Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges and. Remove the nose cup.

3M – 3M Mercury Vapor or Chlorine Acid Gas Cartridge

Respirador de pieza facial completa Serie Using the diaphragm removal tool, turn diaphragm retaining ring counter clockwise and. If the facepiece cartcho slightly and no air leaks are detected between the face and facepiece, a proper seal has. Remove the exhalation valve by grasping and pulling on cartuch edges of the valve.

Todos los derechos reservados. N-series fi lters should not be used in environments containing oils. Replace the valve if necessary. Connect the other end of breathing tube to air regulating valve. P Advanced Particulate Filter with nuisance level acid gas relief.